Dry Cabinet for Integrated Circuits
  • Dry Cabinet for Integrated CircuitsDry Cabinet for Integrated Circuits
  • Dry Cabinet for Integrated CircuitsDry Cabinet for Integrated Circuits
  • Dry Cabinet for Integrated CircuitsDry Cabinet for Integrated Circuits
  • Dry Cabinet for Integrated CircuitsDry Cabinet for Integrated Circuits
  • Dry Cabinet for Integrated CircuitsDry Cabinet for Integrated Circuits

Dry Cabinet for Integrated Circuits

Climatest Symor® is an engineering company in China, that designs and manufactures dry cabinets for integrated circuits, these Dry Cabinet for Integrated Circuits are mainly applied in the fields of electronic & semiconductor industry.

Model: TDU1436BFD-4
Capacity: 1436L
Humidity: <3%RH Automatic
Recovery time: Max. 30 min after open door 30 seconds then closed.
(Ambient 25℃ 60%RH)
Shelves: 5pcs
Color: Dark Blue, ESD safe
Interior dimension: W1198*D682*H1723 MM
Exterior dimension: W1200*D710*H1910 MM

Send Inquiry

Product Description

Description

Climatest Symor® dry cabinets for integrated circuits provide an ultra-low humidity environment, to prevent moisture absorption as well as rust and oxidation, moisture is the invisible killer that threatens your products quality, this threat is not measurable and only becomes aware of in the life cycle of the product, more and more manufacturers begin to notice this problem, and take effective measures.Welcome to buy Dry Cabinet for Integrated Circuits from us.



Dry Cabinet for Integrated Circuits Specification

Mode# with F: ESD function, Dark Blue color. Mode# without F: No ESD function, off white color

Model

Capacity

Interior Dimension

(W×D×H,mm)

Exterior Dimension

(W×D×H,mm)

Average Power (W)

Gross Weight (KG)

Max. Load/shelf (KG)

TDU320BD

320L

898*422*848

900*450*1010

10

70

80

TDU320BFD

320L

898*422*848

900*450*1010

10

70

80

TDU435BD

435L

898*572*848

900*600*1010

10

82

80

TDU435BFD

435L

898*572*848

900*600*1010

10

82

80

TDU540BD

540L

596*682*1298

598*710*1465

10

95

80

TDU540BFD

540L

596*682*1298

598*710*1465

10

95

80

TDU718BD

718L

596*682*1723

598*710*1910

15

105

80

TDU718BFD

718L

596*682*1723

598*710*1910

15

105

80

TDU870BD

870L

898*572*1698

900*600*1890

15

130

100

TDU870BFD

870L

898*572*1698

900*600*1890

15

130

100

TDU1436BD-4

1436L

1198*682*1723

1200*710*1910

25

189

100

TDU1436BFD-4

1436L

1198*682*1723

1200*710*1910

25

189

100

TDU1436BD-6

1436L

1198*682*1723

1200*710*1910

25

189

100

TDU1436BFD-6

1436L

1198*682*1723

1200*710*1910

25

189

100


Dry Cabinet for Integrated Circuits Feature

·Adopts Switzerland original imported humidity & temperature sensor.

-This ensures high accuracy in use, Climatest Symor® dry cabinets for integrated circuits have memory function, no need to re-set after power failure.


·Made by 1.2mm thickness galvanized steel, with USA DuPont ESD painting.

-Reinforced structure design, excellent load-bearing, surface treatment with 18 painting processes, the static resistance value meets 106 -108Ω, also with strong corrosion resistance.


·3.2mm high intensity tempered glass window for better observation.

- Flat press zinc alloy lock, with perfect air tightness and anti-theft function, this dry cabinets for integrated circuits sealing performance is excellent.


·With memory function, no need to re-set after power failure.

-The dry cabinets for integrated circuits can automatically memorize the last setting value after power off, no need set again.


·Powerful dry unit with +15 years projected lifespan.

- The dry cabinets for integrated circuits adopt 4A molecular sieve dry unit, the most advanced technique, it can be regenerated automatically, no need replacement.


·Universal castors installed at bottom, ESD safe.

- Reinforced PU castors are installed at the bottom of dry cabinets for integrated circuits, front two with brakes for easy move and stop.



What is Climatest Symor® dry cabinet for integrated circuits, dry cabinet for PCB, PCBA?

Climatest Symor® dry cabinets for integrated circuits maintain the interior humidity <3%RH, when the moisture sensitive components are stored properly in dry cabinets for integrated circuits, the floor life is extended, the popcorn and micro-cracking phenomenons are not an issue any more, the cabinets suit long-term storage of IC packages, and conform to IPC/JEDEC J-STD- 033 standard.


Climatest Symor® dry cabinet for integrated circuits working principle

Traditional desiccants are consumables, which always need replacement, and very inconvenient, Climatest Symor® auto dry cabinet, dry cabinet for PCB, PCBA use molecular sieve inside dry units, the molecular sieve is the most effective and environment-friendly desiccant, it can be regenerated in use, no need replacement. The whole dehumidifying process is microcomputer controlled, when the interior humidity is high, it will start to absorb moisture; when the humidity reach the setting value, it will stop absorbing, and then discharge the moisture to outside, it is automatic.


<3%RH series dehumidifying speed:

Under ambient 25 degree C, humidity 60%RH, open door 30 seconds and then closed, the humidity will recover to <3%RH within 30 minutes, see below curve:


Application of Climatest Symor® dry cabinet for integrated circuits, dry cabinet for PCB, PCBA

During SMT overflow process, if there is moisture inside IC packages, it 100% causes micro-cracking, the interior die is damaged, wiring get broken, plastics are separated from the die, or lead-frame, these defects are not easy to be noticed in the early stage, some damages extend to the surface, you will see cracking like below pictures, the maintenance is troublesome and even waste of the assembly, It is crucial that these invisible, potential problems enter into the market, then faculty products return and complains.

IPC/JEDEC J-STD-033 standard specifies“Standard for Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices.”, it require low humidity storage for moisture sensitive components.


Electronic dry cabinet features:

*All the models can maintain <3%RH automatic
*Wide range of dry cabinets with different sizes for selection
*Conforms to IPC/JEDEC J-STD-033 standard
*Dehumidifying semiconductor components to prevent popcorn/micro-cracking
*Options like over-humidity buzzer alarm, open door buzzer alarm, data logger
*ESD safe


Electronic dry cabinet characteristics:

1.Module design: The dry cabinets for integrated circuits adopt independent module design, from small spare parts, to temperature & humidity controller, control system and dry units, every module can be quickly replaced, simple maintenance, this greatly improve the maintenance efficiency.
2.Environment-friendly design: The latest module design, the dry cabinets for integrated circuits can be directly upgraded, and the old system modules can be sent back to the original factory. Therefore, the machine will never be obsolete, also it does not produce waste pollution.The powerful electronic drying cabinet is designed for long-term use for more than 15 years.
3.Flexible design: Before purchase, users can add options on dry cabinets for integrated circuits, like over-humidity buzzer alarm, data logger, open door buzzer alarm, three-color tower light, the flexible design offers customers more efficient selection.


We provide dry cabinets for integrated circuits solutions in below industries:

  • Electronic production

  • Semiconductor

  • Pharmaceutical

  • Laboratory

  • Aviation

  • Military


Advantages of dry cabinets for integrated circuits


For more details about dry cabinets for integrated circuits, pls visit our website www.climatestsymor.com or directly send emails to sales@climatestsymor.com, we will get you back at quickest time, welcome for possible collaboration.








Hot Tags: Dry Cabinet for Integrated Circuits, Manufacturers, Suppliers, China, Made in China, Price, Factory
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept