Electronic Humidity Control Dry Cabinets
  • Electronic Humidity Control Dry CabinetsElectronic Humidity Control Dry Cabinets
  • Electronic Humidity Control Dry CabinetsElectronic Humidity Control Dry Cabinets
  • Electronic Humidity Control Dry CabinetsElectronic Humidity Control Dry Cabinets
  • Electronic Humidity Control Dry CabinetsElectronic Humidity Control Dry Cabinets
  • Electronic Humidity Control Dry CabinetsElectronic Humidity Control Dry Cabinets
  • Electronic Humidity Control Dry CabinetsElectronic Humidity Control Dry Cabinets

Electronic Humidity Control Dry Cabinets

Climatest Symor® is China electronic humidity control dry cabinets manufacturer, we make different types of electronic humidity control dry cabinets with cost effective price, each electronic humidity control dry cabinet is supplied with most advanced dehumidifying technology, and come with two years warranty, the humidity is adjustable from 10%RH to 20%RH.

Model: TDB98 (benchtop type)
Capacity: 98L
Humidity: 10-20%RH Adjustable
Recovery time: Max. 30 min after open door 30 seconds then closed. (Ambient 25℃ 60%RH)
Shelves: 1pc, height adjustable
Color: Off white, non-ESD safe
Interior dimension: W446*D372*H598 MM
Exterior dimension: W448*D400*H688 MM

Send Inquiry

Product Description

Description

Climatest Symor® electronic humidity control dry cabinets are compact design with high efficiency, it suits different application, like laboratory, automotive parts, and any application requires low humidity storage, the system absorbs moisture inside the products, and rapidly return RH to the user’s setting RH point, the whole process is silent and environmental.


Specification

Mode# with F: ESD function, Dark Blue color.
Mode# without F: No ESD function, off white color

Model

Capacity

Interior Dimension

(W×D×H,mm)

Exterior Dimension

(W×D×H,mm)

Average Power (W)

Gross Weight (KG)

Max. Load/shelf (KG)

TDB98

98L

446*372*598

448*400*688

6

31

50

TDB98F

98L

446*372*598

448*400*688

6

31

50

TDB160

160L

446*422*848

448*450*1010

6

43

50

TDB160F

160L

446*422*848

448*450*1010

6

43

50

TDB240

240L

596*372*1148

598*400*1310

6

57

50

TDB240F

240L

596*372*1148

598*400*1310

6

57

50

TDB320

320L

898*422*848

900*450*1010

6

70

80

TDB320F

320L

898*422*848

900*450*1010

6

70

80

TDB435

435L

898*572*848

900*600*1010

8

82

80

TDB435F

435L

898*572*848

900*600*1010

8

82

80

TDB540

540L

596*682*1298

598*710*1465

8

95

80

TDB540F

540L

596*682*1298

598*710*1465

8

95

80

TDB718

718L

596*682*1723

598*710*1910

8

105

80

TDB718F

718L

596*682*1723

598*710*1910

8

105

80

TDB870

870L

898*572*1698

900*600*1890

8

130

100

TDB870F

870L

898*572*1698

900*600*1890

8

130

100

TDB1436-4

1436L

1198*682*1723

1200*710*1910

15

189

100

TDB1436F-4

1436L

1198*682*1723

1200*710*1910

15

189

100

TDB1436-6

1436L

1198*682*1723

1200*710*1910

15

189

100

TDB1436F-6

1436L

1198*682*1723

1200*710*1910

15

189

100


Feature

·Adopts Switzerland original imported humidity & temperature sensor.
-This ensures high precision in use, moreover, the electronic humidity control dry cabinets have memory function, no need to re-set after power interrupted.

·Made by 1.2mm thickness galvanized steel, with USA DuPont anti-static powder spraying.
-Firm structure, excellent load-bearing, surface treatment with 18 painting processes, the static resistance value meets 106 -108Ω, moreover, the corrosion resistance is super good.

·3.2mm high intensity tempered glass window for better observation.
- Flat press zinc alloy lock, with perfect air tightness and anti-theft function, the electronic humidity control dry cabinets air-tightness is excellent.

·With memory function, no need to re-set after power failure.
-The electronic humidity control dry cabinets can automatically remember the previous setting value after power off, no need re-set.

·Powerful dry unit with +15 years projected lifespan.
- The electronic humidity control dry cabinets adopts multi-porous molecular sieve as desiccant, it can be regenerated automatically, no consumables and no replacement needed.

·Universal castors equipped at bottom, ESD safe.
- Reinforced PU castors are installed at the bottom, front two with brakes.



Climatest Symor® electronic humidity control dry cabinets, benchtop dry cabinets

Climatest Symor® electronic humidity control dry cabinets, are used to dry moisture sensitive components in a low humidity storage environment, it adopts the auto dehumidifying technology to maintain a humidity level from 20% to 10%RH, no nitrogen needed, no vacuum needed, users just connect the electronic dry cabinet to the power supply, then set the RH point on the LED controller, it will automatically work, the power consumption is low.
The dry unit is the core of the electronic humidity control dry cabinets, it is made by synthetic desiccant, which is self generating, auto-dehumidifying, and maintenance free, this synthetic desiccant lifespan is + 15 years without replacement, there is no cooling drops, no desiccant bags, users just connect it to the power supply, and set RH value, it will automatically proceed dehumidify cycles, absorb and discharge RH intelligently, the whole process is safe and environmental.

Climatest Symor® electronic humidity control dry cabinets use high accuracy Switzerland imported RH sensor, the sensor automatically controls the refreshing and recycling of the synthetic desiccant, the sensor deviation is +/- 2%RH, see below specification:

The electronic humidity control dry cabinets just display the real-time temperature inside for monitoring purpose,it uses high accuracy Switzerland imported temp. sensor, the sensor deviation is +/- 0.3 degree C, see below specification:


Application of electronic humidity control dry cabinets, benchtop dry cabinets

Electronic humidity control dry cabinets are the OPTIMAL storage solution for:
※ Automotive parts, like engine components, bearings, springs, plungers.
※ Pharmaceutical materials, like herbal medicine, pills, capsules, raw material.
※ Military weapons, precision instruments, museum, photos & lens.
※ Moisture-absorbing materials, such as epoxy, resins, adhesive


10%-20%RH Series dehumidifying speed:

Open door 30 seconds and then closed, the humidity will recover to <10%RH within 30 minutes,see below curve: (Ambient 25 degree C, humidity 60%RH)


WHAT ARE THE COMMON METHODS TO STORE HUMIDITY SENSTIVE COMPONENTS?

1.Desiccant bags
❊Method: The moisture sensitive components are packed in a enclosure, the traditional desiccant bags are also put inside the enclosure, it can absorb the moisture inside to keep a dry environment.
❊Disadvantage: Desiccant bag= consumables, RH control performance is bad, short time.

2.Nitrogen cabinets
❊Method: The moisture sensitive components are stored in nitrogen purge cabinets or compressed air to meet low humidity storage.
❊Disadvantage: Nitrogen filling = continuous N2 consumption, high cost.

3.Dry storage cabinets
❊Method: The moisture sensitive components are placed in a dry storage cabinet, just plug in, the machine will automatically work, and reach the setting value.
❊ Advantages: No consumables, no manual work, no nitrogen consumption, environmental, only a little bit of electricity needed.
From above comparison, dry storage cabinet brings you higher efficiency and lower cost, it is the most cost-effective choice in the long term.


We provide benchtop dry storage cabinet solutions to below industries:

  • Electronic production

  • Semiconductor

  • Pharmaceutical

  • Laboratory

  • Aviation

  • Military


Advantages of electronic humidity control dry cabinets


For more details about benchtop dry storage cabinet, pls visit our website www.climatestsymor.com or directly send emails to sales@climatestsymor.com, we will get you back at quickest time, welcome for possible collaboration.








Hot Tags: Electronic Humidity Control Dry Cabinets, Manufacturers, Suppliers, China, Made in China, Price, Factory